AED
Specifications

Avive Connect AED™

Avive Connect AED Specifications

Defibrillator

Model

Type

Selected Energy

Audible Instructions (Emergency)

CPR Guidance

CPR Coaching

 

Indicators

Avive AED™ with Avive Connect™

Fully Automatic

Adult 150 Joules, Pediatric 50 Joules

Detailed audio instructions and visual indicators guide untrained and trained responders through the rescue.

Real-time guidance via audio and visual instructions.

Continuous detailed coaching during CPR with an audible metronome, audio instructions, and countdown, all designed to encourage high performance compressions.

Audio to convey functionality status. Status Light to indicate functionality status. Stand Back Light and audio instructions to indicate when not to touch patient during rescue scenario.

Physical Specifications (with Avive Pad Cartridge Installed)

Dimensions

Weight

5.63 in x 6.30 in x 2.60 in (143 mm x 160 mm x 66 mm)

2.1 lbs (953 grams)

Avive AED dimensions

Environmental

Temperature

  • Operating temperature: 32°F to 122°F (O°C to 50°C)
  • Battery charging: 32°F to 113°F (0°C to 45°C)
  • Short-term storage temperature (up to 14 days): -4°F to 140°F (-20°C to°60 C)
  • Long-term storage temperature: 41°F to 104°F (5°C to 40°C)

Humidity

5-95% non-condensing

Dust / Water Resistance

IP 54 (with Avive Pad Cartridge installed) -dust protected, splash, and spray proof

Altitude

-280 ft to 15,000 ft (-85m to 4572m)

Pad Cartridge Specifications

Shelf Life

2 years (see use-by-date on the pad cartridge)

Electrode Type

Pre-connected, single-use combined ECG / defibrillation pad. Electrode Placement: Adult: Anterior-Lateral; Pediatric: Anterior/Posterior

Battery

Battery Type

 

Time to Full Battery Charge

Capacity (Fully Charged, typical)

Low Battery

Lithium Ion, Rechargeable, not user replaceable

 

< 5 hours

≥ 75 shocks at 150J or 2.5 hours of continuous operation

.

From a fully charged battery at nominal conditions:

≥ 8.5 Months until Low Battery

At Low Battery the AED can deliver < 10 shocks at 150J or < 20 minutes of continuous operation

The screen and connectivity battery will last  5 months at nominal conditions

Avive AED charging

Device Readiness Tests

Automatic

Daily: Battery Status, Basic Circuitry Functionality, Pad Readiness

Weekly: All Daily, plus partial energy charge and discharge cycle

Monthly: All Daily, plus full energy charge and discharge cycle

User-Initiated

Functionality Status: Press and hold the power button for 5 seconds, and the device will share its status.

Connectivity

Wireless Communication Methods

Location

Bluetooth® connection to the Avive App™ and cellular and WiFi connection to the cloud-based REALConnect Platform.

GPS based device tracking

Display

Visual Touchscreen

Visual Prompts

High-resolution color touchscreen

InSync image and motion graphics during emergency mode

Avive AED Front